Backflow Prevention Testing & Installation Services
Annual testing, rebuilding, and installation of commercial and residential backflow assemblies.
Backflow prevention devices protect the public potable drinking water supply from cross-connection contamination caused by back-siphonage or back-pressure. Certified backflow testing, valve rebuilding, and compliant installations are legally mandated across municipal jurisdictions.
Common Causes & Root Factors
- Municipal water main breaks causing sudden negative pressure siphoning non-potable water inward
- Worn rubber check disc seals, relief valves, or springs inside the backflow assembly
- Winter freeze damage cracking bronze valve bodies on outdoor irrigation units
- Debris and sand preventing check valves from closing completely
Observable Warning Signs
- Continuous spitting or water discharge from the atmospheric relief valve vent
- Water authority sending an annual mandatory backflow testing notice
- Noticeable drop in water pressure downstream of the backflow assembly
- Discolored water appearing when outdoor irrigation or boilers cycle on
What Professional Backflow Prevention Testing & Certification Involves
Certified Gauge Hookup
Connect NIST-calibrated differential pressure gauge to device test cocks.
Differential Pressure Testing
Measure exact PSI crack point on check valve 1, check valve 2, and the relief valve.
Internal Rebuild (If Failing)
Disassemble housing, replace rubber check discs, diaphragms, and springs, and flush body.
Official Regulatory Filing
Re-test to confirm pass metrics, tag device, and submit certified paperwork to local water purveyor.
Homeowner Checklist
- Locate your backflow device (often near the water meter or on outdoor lawn irrigation risers)
- Insulate outdoor backflow assemblies before the first autumn freeze
- Do not tamper with shutoff handles or test cocks
Safety Warnings
- Only state-certified backflow testers are legally authorized to test, certify, and tag backflow assemblies
- Cross-connections with boiler chemicals or lawn fertilizers can cause fatal poisoning if backflow fails
Frequently Asked Questions
Why is annual backflow testing legally required?
Municipal codes mandate annual testing because mechanical check valves rely on rubber seals and springs that naturally degrade, risking potable water contamination.
What is the difference between back-siphonage and back-pressure?
Back-siphonage occurs when low pressure in the supply line sucks water backward; back-pressure occurs when downstream pressure exceeds supply pressure, forcing water backward.
Need a Plumber in Your Area?
Call (833) 421-9556 to connect with local plumbing assistance.
Call (833) 421-9556